Get Quick Quote From Supplier
Complete heat exchanger according to the following specifacation and the attached drawings VIII DIVI& TEMA R ASME, SEC Surface area 731 m2 tube size OD 15.9 mm * 2.4th *8800 mm st .l R 35 only th 2.6 mm tube material A213 TP 316 Seamless TUBE NO 968 U-TUBE S . all Dwg no . With C.D 430-20843Dwg NO. 431-*******1-*******1-*******1-*******1-*******1-23845 REQUIREMENTS : _ Material for ( shell side ) all internals partes : supporte plate , tieroad, spacer inner shell & long baffle must be SUS 304 and the back of tube sheet must be cladding by SUS 309 (cooling water side ) 3 mm thickness . _ Painting the inside of shell by epoxy against the galvanic corrosion . _ Elements for cathode protection at shell side . _ X-Ray , UT& Hydrostatic test certificate . _ WPS, PQR & all NDT Reports shall be submitted in a document. _ Third party inspection . _ All DWG shall be approved from our company ( scf ) before manufacturing starting . _ All DWG, Reports shall be submitted in three copies of documents in English language. _ Nitrogen sealing is required for conservation . _ All certificates , reports should be according to ASTM and ASME standards . _ operation guarantee for six month.four engineer visite the manufacturer work shop for inspection &approval complete heat exchanger, heat, exchanger tubes